Relinking Oracle manually is suggested under the following circumstances
(even though the OS vendor may not require it):

- An OS upgrade has occurred.
- A change has been made to the OS system libraries. This can occur during 
the application of an OS patch.
- A new install failed during the relinking phase.
- Individual Oracle executables core dump during initial startup.
- An individual Oracle patch has been applied (however, explicit relink 
instructions are usually either included in the README or integrated into 
the patch install script)  